GPP calculator

Grains per pound (GPP) and dew point from relative humidity and temperature. It is the same math DryLogKit uses for every daily reading.

0 to 100
−40 to 200 °F, or −40 to 93 °C
Temperature unit
At 70 °F and 50 % RH: 54.5 grains per pound, dew point 50.6 °F.

How the numbers are calculated

DryLogKit uses the psychrometric equations in the ASHRAE Handbook — Fundamentals (2017), chapter 1:

  1. Saturation vapour pressure of water, pws, from the Hyland–Wexler equations (Eq. 5 below 0 °C, Eq. 6 above).
  2. Partial vapour pressure pw = RH ÷ 100 × pws.
  3. Humidity ratio W = 0.621945 × pw ÷ (p − pw), with p = 101.325 kPa (sea level).
  4. GPP = W × 7000 grains per pound of dry air.
  5. Dew point from ASHRAE Eq. 39 (Eq. 40 below freezing).

Results are rounded to 0.1. Altitude is not corrected, so at high elevation GPP reads slightly low. Formula version: psy-1 (ASHRAE 2017 Fundamentals ch. 1, sea level 101.325 kPa). Drying reports print this version so old numbers stay reproducible.

Worked examples

GPP worked examples
TemperatureRHGPPDew point
70 °F50 %54.550.6 °F
80 °F60 %92.164.9 °F
90 °F30 %63.054.5 °F
20 °C50 %50.89.3 °C

Using GPP on a water job

Comparing the GPP of affected areas, unaffected areas, outside air and dehumidifier exhaust shows whether the air is drying. A dehumidifier that lowers GPP from inlet to exhaust is removing water; a rising GPP in the affected area can mean more air movement or dehumidification is needed.

IICRC S500 is a voluntary industry standard. This calculator is a convenience: it is not a certification and it does not replace your instruments or your carrier's requirements.

Log readings with GPP in DryLogKit